Fault code lookup

Results for “P201”

Fault codes 48

Results match keywords in the stored descriptions. Codes you typed are shown first.

CodeDescriptionBrandsSystem
P201300Faulty TCU (internally)1Powertrain
P201302Major leak in purge system: hose in system not connected or filler cap open1Powertrain
P201400Swirl position: flag indicating an external fault (due to analogic to digital converter or vext supply)1Powertrain
P201402Purge control system has slight leak: leak in hose connection or shutoff valve of activated charcoal canister1Powertrain
P201500The swirl opened position learnt value is too high (dirty valve or too big dispersion)2Powertrain
P201501The absolute difference between the current swirl opened position learning and the average of the previous learnt values is too high1Powertrain
P201502Purge control system has leak (function chain): mechanical defect in component purge control valve1Powertrain
P201600If the position sensor of VSA output voltage is below threshold value for more than 2 sec., ECM sets DTC. This fault might be caused by open in power circuit or short to ground in signal circuit of VSA position sensor2Powertrain
P201601Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at part load), enrichment over permissible limit1Powertrain
P201602Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at part load), enleanment below permissible limit1Powertrain
Show 13 more matches on this page
CodeDescriptionBrandsSystem
P201700Swirl position out of range check: high or sc to VBATT2Powertrain
P201701Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at idle speed), enrichment over permissible limit1Powertrain
P201702Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at idle speed), enleanment below permissible limit1Powertrain
P201800PCM sets DTC if the PCM detects erratic signal change of VCM position sensor2Powertrain
P201801Self-Adaptation of mixture formation for right bank of cylinders is at limit value (between idle speed and part load), overcorrection of injector mixture1Powertrain
P201802Self-Adaptation of mixture formation for right bank of cylinders is at limit value (between idle speed and part load), under correction of injector mixture1Powertrain
P201908Power output limited because of excessively high temperature of coolant1Powertrain
P201B01Voltage supply of component ECU: battery voltage too high1Powertrain
P201B02Voltage supply of component ECU: battery voltage is too low1Powertrain
P201B08Voltage supply of component ECU: battery voltage too low for ADC1Powertrain
P201C01Fuel tank pressure sensor: short circuit to positive1Powertrain
P201C02Fuel tank pressure sensor: short circuit to ground1Powertrain
P201C04Fuel tank pressure sensor: open circuit1Powertrain
CodeDescriptionBrandsSystem
P201700Swirl position out of range check: high or sc to VBATT2Powertrain
P201701Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at idle speed), enrichment over permissible limit1Powertrain
P201702Self-Adaptation of mixture formation for right bank of cylinders is at limit value (at idle speed), enleanment below permissible limit1Powertrain
P201800PCM sets DTC if the PCM detects erratic signal change of VCM position sensor2Powertrain
P201801Self-Adaptation of mixture formation for right bank of cylinders is at limit value (between idle speed and part load), overcorrection of injector mixture1Powertrain
P201802Self-Adaptation of mixture formation for right bank of cylinders is at limit value (between idle speed and part load), under correction of injector mixture1Powertrain
P201908Power output limited because of excessively high temperature of coolant1Powertrain
P201B01Voltage supply of component ECU: battery voltage too high1Powertrain
P201B02Voltage supply of component ECU: battery voltage is too low1Powertrain
P201B08Voltage supply of component ECU: battery voltage too low for ADC1Powertrain
P201C01Fuel tank pressure sensor: short circuit to positive1Powertrain
P201C02Fuel tank pressure sensor: short circuit to ground1Powertrain
P201C04Fuel tank pressure sensor: open circuit1Powertrain
Advanced: scanner vehicle and live-data matches

Vehicles 2

Vehicle data covers only some brands. These matches come from scanner data, not from a full vehicle index, so treat them as approximate.

BrandModel / variantDetails
ChryslerP2010 SHORT RUNNER SOLENOID CIRCUIT HIGH or CHARGE AIR COOLER CIRCULATION PUMP CONTROL CKT HIGHcode P023C
HyundaiIf faulty VSA motor control circuit is detected for more than 2 sec., ECM sets DTC. This fault might be caused by open or short to ground in control circuit of VSA. If open in control circuit is detected, DTC P201500 is also setcode P200900

Live data 0

No matching live-data parameters.

These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.

OpenDTC - independent fault code reference