| Code | Description | Brands | System |
|---|---|---|---|
| U02B629 | Das Signal INP_BSM_Md_Stat oder BSM_Disp_Rq_ST3 oder BSM_Md_Stat_ST3 oder BSM_Warn_Lt_Rq_ST3 oder BSM_Warn_Rt_Rq_ST3 wird mit einem ungültigem Wert empfangen | 1 | Network |
| U02B683 | Protocol Error Slave | 1 | Network |
| U02B687 | Lost Communication Radar Slave | 1 | Network |
| U02BC83 | Protocol Error POS | 1 | Network |
| U02BC87 | Lost Communication POS | 1 | Network |
| U0300 | Internal Control Module Software Incompatibility | 36 | Network |
| U030000 | CAT1 or CAT2 reset occured | 3 | Network |
| U030001 | E3 Sw ErrorSopc | 1 | Network |
| U030002 | An internal fault has occurred in the control unit software. General Signal Failure. | 1 | Network |
| U030004 | software error in variable pool (only development) | 1 | Network |
| U030005 | Lockstep fault | 1 | Network |
| U030006 | software error in time based memory management (only development) | 1 | Network |
| U030007 | software error in errorhandler (only development) | 1 | Network |
| U030009 | An internal fault has occurred in the control unit software. There is a component fault. | 1 | Network |
| U030031 | An internal fault has occurred in the control unit software. No Signal. | 1 | Network |
| U030041 | An internal fault has occurred in the control unit software. General Checksum Failure | 1 | Network |
| U030042 | An internal fault has occurred in the control unit software. There is a general memory error. | 1 | Network |
| U030043 | An internal fault has occurred in the control unit software. There is an error in the additional memory. | 1 | Network |
| U030046 | An internal fault has occurred in the control unit software. Calibration / Parameter Memory Failure | 1 | Network |
| U030047 | Error in task monitoring | 2 | Network |
| U030048 | software error in buffer management | 1 | Network |
| U030052 | Array output indicating Inverter Temperature Sensor Noisy fault symptom status for each of the available inverter temperature sensors. | 1 | Network |
| U030053 | Array output indicating Inverter Temperature Sensor Stuck in Range fault symptom status for each of the available inverter temperature sensors. | 1 | Network |
| U030054 | An internal fault has occurred in the control unit software. Missing Calibration | 1 | Network |
| U030055 | Array output indicating Inverter Temperature Sensor Circuit Short to Battery fault symptom status for each of the available inverter temperature sensors. | 2 | Network |
| U030056 | An internal fault has occurred in the control unit software. Invalid / Incompatible Configuration | 1 | Network |
| U030057 | An internal fault has occurred in the control unit software. Invalid / Incompatible Software Component. | 1 | Network |
| U030061 | ADC test command feedback voltage - Too Low | 1 | Network |
| U030062 | ADC test command feedback voltage - Too High | 1 | Network |
| U030064 | An internal fault has occurred in the control unit software. Signal Plausibility Failure. | 1 | Network |
| U030068 | The DC Current sensor short to ground fault | 1 | Network |
| U030071 | The DC Current sensor out of range low fault. | 1 | Network |
| U030072 | The DC Current sensor offset out of range fault | 1 | Network |
| U030073 | 15V HV Voltage - Too Low | 1 | Network |
| U030074 | 15V LV Voltage - Too High | 1 | Network |
| U030092 | An internal fault has occurred in the control unit software. Performance or Incorrect Operation | 1 | Network |
| U030093 | Pump1 Motor Bridge Sensot Temp -Too high | 1 | Network |
| U030094 | Pump2 Motor Bridge Sensor Temp -Too high | 1 | Network |
| U030097 | An internal fault has occurred in the control unit software. Component or System Operation Obstructed or Blocked. | 1 | Network |
| U03009A | An internal fault has occurred in the control unit software. Component or System Operating Conditions. | 1 | Network |
| U0300E0 | An internal fault has occurred in the control unit software. | 1 | Network |
| U0300E1 | In einem der Signale IPC_M_HMHQ_EHR_EI_CUM_SQC_POM, IPC_M_HMHQ_EHR_EI_CUM_CRC_POM, IPC_M_HMHQ_EHR_EI_CUM_SQC_PRF, IPC_M_HMHQ_EHR_EI_CUM_CRC_PRF wird ein Fehler angezeigt | 1 | Network |
| U0300E2 | An internal fault has occurred in the control unit software. | 1 | Network |
| U0300E3 | Internal Control Module Software Incompatibility | 1 | Network |
| U0300E4 | An internal fault has occurred in the control unit software. S/W modules on QNX reported errors in SLog2 with verbosity 'ERROR' | 1 | Network |
| U0300E5 | An internal fault has occurred in the control unit software. S/W modules on QNX reported errors in SLog2 with verbosity 'CRITICAL' | 1 | Network |
| U0300E6 | Error related to Exception that occured | 1 | Network |
| U0300E7 | An internal fault has occurred in the control unit software. Error during mP shut-off path test | 1 | Network |
| U0300E8 | Added for future purpose | 1 | Network |
| U0300E9 | An internal fault has occurred in the control unit software. Error during the state change | 1 | Network |
Some brand data is extracted from diagnostic files and may contain manufacturer-specific wording. General SAE J2012 descriptions are used where available.