Results for “P0C0”
Fault codes 23
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P0C00 | Controller button stuck | 22 | Powertrain |
| P0C01 | Controller hardware overcurrent | 28 | Powertrain |
| P0C02 | Rearview mirror mechanism sensor input failure | 26 | Powertrain |
| P0C03 | Keyboard button stuck | 21 | Powertrain |
| P0C04 | External temperature sensor fault | 26 | Powertrain |
| P0C05 | Drive motor 'A' phase U-V-W circuit/open | 25 | Powertrain |
| P0C06 | Drive motor 'A' phase U-V-W circuit low | 21 | Powertrain |
| P0C07 | Rearview mirror vertical position failure | 21 | Powertrain |
| P0C08 | Rearview mirror horizontal position failure | 24 | Powertrain |
| P0C09 | Drive motor 'B' phase U-V-W circuit low | 21 | Powertrain |
Show 13 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P0C0A | Lighting output failure of door electronic equipment (door sill, door controller, keyboard, keyboard indicator light) | 19 | Powertrain |
| P0C0B | Internal failure of power window motor | 24 | Powertrain |
| P0C0C | Drive Motor A Inverter Power Supply Circuit Low | 25 | Powertrain |
| P0C0D | Rearview mirror mechanism control output failure | 23 | Powertrain |
| P0C0E | Rearview mirror de-icing output failure | 22 | Powertrain |
| P0C0F | Storage keyboard lighting failure | 19 | Powertrain |
| P0C0100 | No description available | 1 | Powertrain |
| P0C0200 | Der Stromwert der Elektrischen Maschine B ist unregelmig. | 1 | Powertrain |
| P0C0219 | The current value of electric machine B is erratic. The limit value for current has been exceeded. | 1 | Powertrain |
| P0C0811 | High Voltage Interlock Hvac short to ground | 1 | Powertrain |
| P0C0812 | High Voltage Interlock Hvac Short to battery | 1 | Powertrain |
| P0C0813 | Phase A Open Fault | 1 | Powertrain |
| P0C0B16 | The power supply of the high-voltage on-board electrical system for inverter 'Electric machine A' has an open circuit. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P0C0A | Lighting output failure of door electronic equipment (door sill, door controller, keyboard, keyboard indicator light) | 19 | Powertrain |
| P0C0B | Internal failure of power window motor | 24 | Powertrain |
| P0C0C | Drive Motor A Inverter Power Supply Circuit Low | 25 | Powertrain |
| P0C0D | Rearview mirror mechanism control output failure | 23 | Powertrain |
| P0C0E | Rearview mirror de-icing output failure | 22 | Powertrain |
| P0C0F | Storage keyboard lighting failure | 19 | Powertrain |
| P0C0100 | No description available | 1 | Powertrain |
| P0C0200 | Der Stromwert der Elektrischen Maschine B ist unregelmig. | 1 | Powertrain |
| P0C0219 | The current value of electric machine B is erratic. The limit value for current has been exceeded. | 1 | Powertrain |
| P0C0811 | High Voltage Interlock Hvac short to ground | 1 | Powertrain |
| P0C0812 | High Voltage Interlock Hvac Short to battery | 1 | Powertrain |
| P0C0813 | Phase A Open Fault | 1 | Powertrain |
| P0C0B16 | The power supply of the high-voltage on-board electrical system for inverter 'Electric machine A' has an open circuit. The limit value for electrical voltage has not been attained. | 1 | Powertrain |