Results for “C”
Fault codes 9,949
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| C209600 | CAN communication: startup signal error | 1 | Chassis |
| C209700 | CAN speed signal invalid | 1 | Chassis |
| C209800 | Yrs2 signal has an INIT status failure | 1 | Chassis |
| C209900 | Yrs2 signal value contains Invalid Value pattern | 2 | Chassis |
| C209A00 | Yrs2 signal is faulty (permanent). | 1 | Chassis |
| C20A300 | Flexray: Signal Anforderung LED Taster Aktive Dämpfungskontrolle ein (ADC_SwLED_Rq_V2) vom SPC ungueltig. | 1 | Chassis |
| C20A800 | Ax2 signal has an INIT status failure | 1 | Chassis |
| C20A900 | Ax2 signal value contains Invalid Value pattern | 1 | Chassis |
| C20AA00 | Ax2 signal is faulty (permanent). | 1 | Chassis |
| C20B100 | Redundancy error for yaw rate sensors detected | 1 | Chassis |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| C20B200 | Offset error for yaw rate sensor 2 detected | 1 | Chassis |
| C20D700 | Flexray: Signal IC hat Stillstandskoordinator-Fehler erkannt (SPCR_Flt_IC) vom EIS/IC ungueltig. | 1 | Chassis |
| C20D800 | Flexray: Signal PN14 hat Stillstandskoordinator-Fehler erkannt (SPCR_Flt_PN14) vom EIS/BC_F ungueltig. | 1 | Chassis |
| C20D900 | Flexray: Signal Status Stillstand (SPCR_Sp_Stat_BC_F) vom EIS/BC_F ungueltig. | 1 | Chassis |
| C210000 | The power supply clamp 30 is too low. | 2 | Chassis |
| C210004 | The power supply at input 'Circuit 30' is too low. There is an internal fault. | 1 | Chassis |
| C210009 | The power supply at input 'Circuit 30' is too low. There is a component fault. | 1 | Chassis |
| C210074 | Left Electronic Parking Brake (EPB) actuator abnormal operation | 1 | Chassis |
| C210077 | Left Electronic Parking Brake (EPB) actuator stall | 1 | Chassis |
| C21009A | Die Spannungsversorgung am Eingang 'Klemme 30' ist zu gering. Component or System Operating Conditions. | 1 | Chassis |
| C2100FA | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C2100FB | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C2100FC | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C210100 | OBD relevant DTC in RBS. For detailed information read Fault Memory of RBS | 2 | Chassis |
| C210174 | Right Electronic Parking Brake (EPB) actuator abnormal operation | 1 | Chassis |
| Code | Description | Brands | System |
|---|---|---|---|
| C20B200 | Offset error for yaw rate sensor 2 detected | 1 | Chassis |
| C20D700 | Flexray: Signal IC hat Stillstandskoordinator-Fehler erkannt (SPCR_Flt_IC) vom EIS/IC ungueltig. | 1 | Chassis |
| C20D800 | Flexray: Signal PN14 hat Stillstandskoordinator-Fehler erkannt (SPCR_Flt_PN14) vom EIS/BC_F ungueltig. | 1 | Chassis |
| C20D900 | Flexray: Signal Status Stillstand (SPCR_Sp_Stat_BC_F) vom EIS/BC_F ungueltig. | 1 | Chassis |
| C210000 | The power supply clamp 30 is too low. | 2 | Chassis |
| C210004 | The power supply at input 'Circuit 30' is too low. There is an internal fault. | 1 | Chassis |
| C210009 | The power supply at input 'Circuit 30' is too low. There is a component fault. | 1 | Chassis |
| C210074 | Left Electronic Parking Brake (EPB) actuator abnormal operation | 1 | Chassis |
| C210077 | Left Electronic Parking Brake (EPB) actuator stall | 1 | Chassis |
| C21009A | Die Spannungsversorgung am Eingang 'Klemme 30' ist zu gering. Component or System Operating Conditions. | 1 | Chassis |
| C2100FA | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C2100FB | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C2100FC | The power supply at input 'Circuit 30' is too low. | 1 | Chassis |
| C210100 | OBD relevant DTC in RBS. For detailed information read Fault Memory of RBS | 2 | Chassis |
| C210174 | Right Electronic Parking Brake (EPB) actuator abnormal operation | 1 | Chassis |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.