Results for “U”
Fault codes 7,936
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| U3F8C00 | DriverWarning due to FuSi cyclic Errors | 1 | Network |
| U3F8D00 | DriverWarning due to FuSi Errors which get reported fast/rapid | 1 | Network |
| U3F8F00 | At least one Hs-Side report bit IntBus ERR bit set in error register | 1 | Network |
| U3F9400 | LV_MON_ERR bit set in error register | 1 | Network |
| U3F9500 | General ASIC error. At least one Ls-Side report bit ASIC ERR bit set in error register | 1 | Network |
| U3F9600 | General ASIC error. At least one Hs-Side report bit ASIC ERR bit set in error register | 1 | Network |
| U3F9A00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_CPC_PT4_SubNWs_GW_SigR1_ST3 (CPC Signal routings to PT Sub Networks) | 1 | Network |
| U3F9B00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_DIAG_Stat_ST3 (Actv Line state Tester pres) | 1 | Network |
| U3F9C00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_PN14_Master_Stat1_ST3 (Powernetwork 12V master state) | 1 | Network |
| U3F9D00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_PT4_EngCoor_OBD2_ST3 (PT4 engine Coor OBD2 ST3) | 1 | Network |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| U3F9E00 | plausibilisation of T15-signal | 1 | Network |
| U3F9F00 | heater current diagnosis | 1 | Network |
| U3FA600 | Diagnosis of short to ground (out of low range) of temperature signal(s) which is located between master path 48V side S9 and slave path 48V side S9 | 1 | Network |
| U3FA700 | Diagnosis of short to battery (out of high range) of temperature signal(s) which is located between master path LV side S9 and slave path LV side S9 | 1 | Network |
| U3FB000 | Diagnosis of current control in forward mode | 1 | Network |
| U3FB300 | coolant intake rotor temperature short circuit to ground | 1 | Network |
| U3FB400 | coolant intake rotor temperature during short circuit to battery detected | 1 | Network |
| U3FCA00 | UART communication failure during Electric machine capacitance status monitoring. | 1 | Network |
| U3FCD00 | Check of Hw signal for reporting, that emergency supply for the ECU is available | 1 | Network |
| U3FCF00 | Dlc Error DFC for the frame ZEVOBDCoor_ST3 | 1 | Network |
| U3FD700 | Frequency monitoring of latency fault check Vdd5v Mon (BIST9) over all Asics | 1 | Network |
| U3FD800 | frequency monitoring of latency fault check VDS external circuit (BIST10) over all Hs Asics | 1 | Network |
| U3FDB00 | Secondary supply voltage under/overvoltage error at LDO_VCC of the HighSide ASICs. At least one HighSide ASIC report either LDO_VCC_UV/OV_ERR bit in error register | 1 | Network |
| U3FDF00 | Rotor position Cos or Sin signal out of range detected in the monitoring SW | 1 | Network |
| U3FE800 | Coolant temperature plausibility check | 1 | Network |
| Code | Description | Brands | System |
|---|---|---|---|
| U3F9E00 | plausibilisation of T15-signal | 1 | Network |
| U3F9F00 | heater current diagnosis | 1 | Network |
| U3FA600 | Diagnosis of short to ground (out of low range) of temperature signal(s) which is located between master path 48V side S9 and slave path 48V side S9 | 1 | Network |
| U3FA700 | Diagnosis of short to battery (out of high range) of temperature signal(s) which is located between master path LV side S9 and slave path LV side S9 | 1 | Network |
| U3FB000 | Diagnosis of current control in forward mode | 1 | Network |
| U3FB300 | coolant intake rotor temperature short circuit to ground | 1 | Network |
| U3FB400 | coolant intake rotor temperature during short circuit to battery detected | 1 | Network |
| U3FCA00 | UART communication failure during Electric machine capacitance status monitoring. | 1 | Network |
| U3FCD00 | Check of Hw signal for reporting, that emergency supply for the ECU is available | 1 | Network |
| U3FCF00 | Dlc Error DFC for the frame ZEVOBDCoor_ST3 | 1 | Network |
| U3FD700 | Frequency monitoring of latency fault check Vdd5v Mon (BIST9) over all Asics | 1 | Network |
| U3FD800 | frequency monitoring of latency fault check VDS external circuit (BIST10) over all Hs Asics | 1 | Network |
| U3FDB00 | Secondary supply voltage under/overvoltage error at LDO_VCC of the HighSide ASICs. At least one HighSide ASIC report either LDO_VCC_UV/OV_ERR bit in error register | 1 | Network |
| U3FDF00 | Rotor position Cos or Sin signal out of range detected in the monitoring SW | 1 | Network |
| U3FE800 | Coolant temperature plausibility check | 1 | Network |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.