Fault code lookup

Results for “P”

Fault codes 32,087

Results match keywords in the stored descriptions. Codes you typed are shown first.

CodeDescriptionBrandsSystem
P1D65This DTC has been stored in accordance with the detection of DTC P0DA8, P0AE1 or7Powertrain
P1D66Current is below lower limit7Powertrain
P1D67A/C Compressor High Voltage Circuit Malfunction7Powertrain
P1D68Electric Heater High Voltage Circuit Malfunction7Powertrain
P1D69Hardware overcurrent7Powertrain
P1D6AIG1 Signal Malfunction(Battery Condition Monitor Module A)5Powertrain
P1D6BHigh single-phase current5Powertrain
P1D6CThermal Damage to Clutches8Powertrain
P1D6DCurrent is above upper limit5Powertrain
P1D6ETraction Motor Temperature Sensor Circuit Performance6Powertrain
Show 15 more matches on this page
CodeDescriptionBrandsSystem
P1D6FMotor Control Unit (MCU) - MOS temperature exceeds limit value7Powertrain
P1D70Insulated Gate Bipolar Transistor (IGBT) fault7Powertrain
P1D71Motor control unit (MCU) temperature sensor sampling value exceeds the valid range14Powertrain
P1D72U phase current sensor sampling value exceeds the valid range16Powertrain
P1D73V phase current sensor sampling value is lower than the valid range8Powertrain
P1D74Phase current sensor sampling value is too large14Powertrain
P1D75Motor control unit (MCU) excitation current sensor sampling value exceeds the valid range8Powertrain
P1D76DC bus three-phase line interlocking line abnormal (short circuit or open circuit)7Powertrain
P1D77Excitation line interlock circuit abnormal (short circuit or open circuit)16Powertrain
P1D78Park Solenoid Circuit Low15Powertrain
P1D79Park Solenoid Circuit High15Powertrain
P1D7AU phase circuit interruption13Powertrain
P1D7BV phase circuit interruption6Powertrain
P1D7CW phase circuit interruption6Powertrain
P1D7DMotor control unit (MCU) excitation line abnormal (short circuit or open circuit)4Powertrain
CodeDescriptionBrandsSystem
P1D6FMotor Control Unit (MCU) - MOS temperature exceeds limit value7Powertrain
P1D70Insulated Gate Bipolar Transistor (IGBT) fault7Powertrain
P1D71Motor control unit (MCU) temperature sensor sampling value exceeds the valid range14Powertrain
P1D72U phase current sensor sampling value exceeds the valid range16Powertrain
P1D73V phase current sensor sampling value is lower than the valid range8Powertrain
P1D74Phase current sensor sampling value is too large14Powertrain
P1D75Motor control unit (MCU) excitation current sensor sampling value exceeds the valid range8Powertrain
P1D76DC bus three-phase line interlocking line abnormal (short circuit or open circuit)7Powertrain
P1D77Excitation line interlock circuit abnormal (short circuit or open circuit)16Powertrain
P1D78Park Solenoid Circuit Low15Powertrain
P1D79Park Solenoid Circuit High15Powertrain
P1D7AU phase circuit interruption13Powertrain
P1D7BV phase circuit interruption6Powertrain
P1D7CW phase circuit interruption6Powertrain
P1D7DMotor control unit (MCU) excitation line abnormal (short circuit or open circuit)4Powertrain
Advanced: scanner vehicle and live-data matches

Vehicles 0

No matching vehicles.

Live data 0

No matching live-data parameters.

These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.

OpenDTC - independent fault code reference