Results for “P0AA”
Fault codes 79
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P0AA49F | The contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. The switch is jammed closed. | 1 | Powertrain |
| P0AA61A | There is an insulation fault in the hybrid/high-voltage on-board electrical system. Circuit Resistance Below Threshold. | 1 | Powertrain |
| P0AA61E | Hybrid Battery Voltage System Isolation Fault. circuit resistance out of range | 1 | Powertrain |
| P0AA649 | There is an insulation fault in the hybrid/high-voltage on-board electrical system. There is an internal electrical fault. | 1 | Powertrain |
| P0AA700 | Hybrid Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA703 | IMD isolation measure path stuck | 1 | Powertrain |
| P0AA704 | Hybrid/EV Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA706 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Algorithm Based Failure. | 1 | Powertrain |
| P0AA707 | IMD isolation measure path stuck | 1 | Powertrain |
| P0AA708 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Bus Signal / Message Failure. | 1 | Powertrain |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P0AA709 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Component Failure. | 1 | Powertrain |
| P0AA716 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Below Threshold. | 1 | Powertrain |
| P0AA717 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Above Threshold. | 1 | Powertrain |
| P0AA71C | Hybrid Battery Voltage Isolation Sensor Circuit. circuit voltage out of range | 1 | Powertrain |
| P0AA71E | The ohmmeter for isolation resistance in the high-voltage battery module has an electrical fault. | 1 | Powertrain |
| P0AA742 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. General Memory Failure. | 1 | Powertrain |
| P0AA747 | Hybrid/EV Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA748 | Hybrid/EV Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA749 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Internal Electronic Failure. | 1 | Powertrain |
| P0AA761 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Calculation Failure. | 1 | Powertrain |
| P0AA764 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Plausibility Failure. | 1 | Powertrain |
| P0AA784 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Below Allowable Range. | 1 | Powertrain |
| P0AA785 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Above Allowable Range. | 1 | Powertrain |
| P0AA7A3 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. System Voltage High. | 1 | Powertrain |
| P0AA7FA | Hybrid/EV Battery Voltage Isolation Sensor Circuit. FA | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P0AA709 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Component Failure. | 1 | Powertrain |
| P0AA716 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Below Threshold. | 1 | Powertrain |
| P0AA717 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Above Threshold. | 1 | Powertrain |
| P0AA71C | Hybrid Battery Voltage Isolation Sensor Circuit. circuit voltage out of range | 1 | Powertrain |
| P0AA71E | The ohmmeter for isolation resistance in the high-voltage battery module has an electrical fault. | 1 | Powertrain |
| P0AA742 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. General Memory Failure. | 1 | Powertrain |
| P0AA747 | Hybrid/EV Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA748 | Hybrid/EV Battery Voltage Isolation Sensor Circuit | 1 | Powertrain |
| P0AA749 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Internal Electronic Failure. | 1 | Powertrain |
| P0AA761 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Calculation Failure. | 1 | Powertrain |
| P0AA764 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Plausibility Failure. | 1 | Powertrain |
| P0AA784 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Below Allowable Range. | 1 | Powertrain |
| P0AA785 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Signal Above Allowable Range. | 1 | Powertrain |
| P0AA7A3 | The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. System Voltage High. | 1 | Powertrain |
| P0AA7FA | Hybrid/EV Battery Voltage Isolation Sensor Circuit. FA | 1 | Powertrain |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.