Results for “P”
Fault codes 32,087
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P2BCC07 | The contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit is jammed closed. There is a mechanical fault. | 1 | Powertrain |
| P2BCCFA | Battery Charging System Negative Contactor 'B' Stuck Closed. FA | 1 | Powertrain |
| P2BCD00 | The contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit is jammed open. | 1 | Powertrain |
| P2BCD07 | The contact 'Negative terminal' of the contactor in the on-board DC current charge-connection unit is jammed open. There is a mechanical fault. | 1 | Powertrain |
| P2BE000 | The 'Coolant level' sensor of the low-temperature circuit has an electrical fault. | 1 | Powertrain |
| P2BE184 | The 'Coolant level' sensor of the low-temperature circuit has a malfunction. There is a signal below the permissible limit value. | 1 | Powertrain |
| P2BE185 | The 'Coolant level' sensor of the low-temperature circuit has a malfunction. There is a signal above the permissible limit value. | 1 | Powertrain |
| P2BE402 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. General Signal Failure. | 1 | Powertrain |
| P2BE409 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Component Failure. | 1 | Powertrain |
| P2BE417 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. The limit value for electrical voltage has been exceeded. | 1 | Powertrain |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P2BE418 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Below Threshold. | 1 | Powertrain |
| P2BE419 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Above Threshold. | 1 | Powertrain |
| P2BE41D | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Out of Range. | 1 | Powertrain |
| P2BE429 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Signal Invalid. | 1 | Powertrain |
| P2BE456 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Invalid / Incompatible Configuration. | 1 | Powertrain |
| P2BE496 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Component Internal Failure. | 1 | Powertrain |
| P2BE49A | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Component or System Operating Conditions. | 1 | Powertrain |
| P2BE516 | Sensor C for the battery current in the hybrid/high-voltage battery module has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P2BE814 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. There is a short circuit to ground or an open circuit. | 1 | Powertrain |
| P2BE816 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P2BE817 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The limit value for electrical voltage has been exceeded. | 1 | Powertrain |
| P2BE9F1 | DTC is set | 1 | Powertrain |
| P2C851A | There is a vehicle-side insulation fault in the hybrid/high-voltage on-board electrical system. Circuit Resistance Below Threshold. | 1 | Powertrain |
| P2C85FA | Hybrid/EV Battery Voltage External Isolation Fault. FA | 1 | Powertrain |
| P2C8600 | Hybrid/EV Battery Voltage Internal Isolation Warning. | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P2BE418 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Below Threshold. | 1 | Powertrain |
| P2BE419 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Above Threshold. | 1 | Powertrain |
| P2BE41D | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Circuit Current Out of Range. | 1 | Powertrain |
| P2BE429 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Signal Invalid. | 1 | Powertrain |
| P2BE456 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Invalid / Incompatible Configuration. | 1 | Powertrain |
| P2BE496 | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Component Internal Failure. | 1 | Powertrain |
| P2BE49A | Sensor C for the battery current in the hybrid/high-voltage battery module has an electrical fault. Component or System Operating Conditions. | 1 | Powertrain |
| P2BE516 | Sensor C for the battery current in the hybrid/high-voltage battery module has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P2BE814 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. There is a short circuit to ground or an open circuit. | 1 | Powertrain |
| P2BE816 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P2BE817 | The output for the switch 'Precharging' at battery string B of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The limit value for electrical voltage has been exceeded. | 1 | Powertrain |
| P2BE9F1 | DTC is set | 1 | Powertrain |
| P2C851A | There is a vehicle-side insulation fault in the hybrid/high-voltage on-board electrical system. Circuit Resistance Below Threshold. | 1 | Powertrain |
| P2C85FA | Hybrid/EV Battery Voltage External Isolation Fault. FA | 1 | Powertrain |
| P2C8600 | Hybrid/EV Battery Voltage Internal Isolation Warning. | 1 | Powertrain |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.