Results for “P”
Fault codes 32,087
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P0ADF00 | Actuation of contact 'Negative terminal' of the contactor in the high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0AE000 | The actuation of contact 'Negative terminal' of the contactor in the high-voltage battery has a short circuit to positive. | 1 | Powertrain |
| P0AE14B | The switch 'Precharging' in the hybrid/high-voltage battery module has an electrical fault. There is a fault due to overtemperature. | 1 | Powertrain |
| P0AE200 | Displaycode | 1 | Powertrain |
| P0AE372 | The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the open position. The actuator does not close. | 1 | Powertrain |
| P0AE413 | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. There is an open circuit. | 1 | Powertrain |
| P0AE49F | The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The switch is jammed closed. | 1 | Powertrain |
| P0AE500 | Pre-charge contactor HSD output over current | 1 | Powertrain |
| P0AE600 | The output for the 'Precharging' switch in the high-voltage battery module has a short circuit to ground. | 1 | Powertrain |
| P0AE700 | The output for the 'Precharging' switch in the high-voltage battery module has a short circuit to positive. | 1 | Powertrain |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P0AE801 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Electrical Failure. | 1 | Powertrain |
| P0AE802 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Signal Failure. | 1 | Powertrain |
| P0AE809 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. Component Failure. | 1 | Powertrain |
| P0AE815 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. There is a short circuit to positive or an open circuit. | 1 | Powertrain |
| P0AE900 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0AE984 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal below the permissible limit value. | 1 | Powertrain |
| P0AE985 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal above the permissible limit value. | 1 | Powertrain |
| P0AEA00 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0AEA11 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a short circuit to ground. | 1 | Powertrain |
| P0AED11 | Out-of-range high on PCB temperature sensor 2 | 1 | Powertrain |
| P0AED12 | Out-of-range low on PCB temperature sensor 2 | 1 | Powertrain |
| P0AED27 | Der Temperatursensor A des Wechselrichters 'Elektrische Maschine' hat einen elektrischen Fehler. The signal change rate is above the permissible limit value. | 1 | Powertrain |
| P0AED85 | Inverter Temperature Sensor AL Out of Range High | 1 | Powertrain |
| P0AEE00 | Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine A' hat Funktionsstörung. | 2 | Powertrain |
| P0AEE16 | Temperature sensor A of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P0AE801 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Electrical Failure. | 1 | Powertrain |
| P0AE802 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Signal Failure. | 1 | Powertrain |
| P0AE809 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. Component Failure. | 1 | Powertrain |
| P0AE815 | Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. There is a short circuit to positive or an open circuit. | 1 | Powertrain |
| P0AE900 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0AE984 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal below the permissible limit value. | 1 | Powertrain |
| P0AE985 | Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal above the permissible limit value. | 1 | Powertrain |
| P0AEA00 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0AEA11 | Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a short circuit to ground. | 1 | Powertrain |
| P0AED11 | Out-of-range high on PCB temperature sensor 2 | 1 | Powertrain |
| P0AED12 | Out-of-range low on PCB temperature sensor 2 | 1 | Powertrain |
| P0AED27 | Der Temperatursensor A des Wechselrichters 'Elektrische Maschine' hat einen elektrischen Fehler. The signal change rate is above the permissible limit value. | 1 | Powertrain |
| P0AED85 | Inverter Temperature Sensor AL Out of Range High | 1 | Powertrain |
| P0AEE00 | Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine A' hat Funktionsstörung. | 2 | Powertrain |
| P0AEE16 | Temperature sensor A of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.