Results for “U”
Fault codes 7,936
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| U220041 | Check to see if DTC IAM- is stored | 1 | Network |
| U230055 | Unexpected fault codes B012654 and | 1 | Network |
| U230056 | The DTC is cleared in the control module | 1 | Network |
| U230100 | CAN: bus-off can-controller 2 | 1 | Network |
| U25BD86 | Lost Communication with Fan 4. Signal Invalid | 1 | Network |
| U2E02FF | Network: External: FW_ComScl_CMS_PI_State_Gw_AR2_CMS_PI_Stat_Pr2_Timeout | 1 | Network |
| U2E03FF | Network: External: FW_ComScl_GW_PT_ObjIntrst_Pr2 - Datacorrupt Error | 1 | Network |
| U2E04FF | Network: External: FW_ComScl_GW_PT_ObjIntrst_Pr2_Timeout | 1 | Network |
| U2E05FF | Network: External: FW_ComScl_GW_VehAccel_X_Rq_Pr2 - Datacorrupt Error | 1 | Network |
| U2E06FF | Network: External: FW_ComScl_GW_VehAccel_X_Rq_Pr2_Timeout | 1 | Network |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| U2E07FF | Network: External: FW_Scl_GW_AS_Actv_Ctrl_Stat_Invalid | 1 | Network |
| U2E14FF | Network: External: FW_ComScl_ESP_EDIFF_Rs_Timeout | 1 | Network |
| U300000 | Monitoring level 2 MU_Error_Md | 3 | Network |
| U300001 | If the customer returns repeatedly to the workshop with the DTC SRS- set, this may indicate that the battery voltage is poor | 3 | Network |
| U300002 | software error in errorhandler (only development) | 2 | Network |
| U300004 | The control unit has a malfunction due to redundant monitoring. There is an internal fault. | 2 | Network |
| U300005 | Lockstep fault | 2 | Network |
| U300006 | If DTC FSM- is stored, prioritise its fault tracing | 3 | Network |
| U300016 | The control unit has a malfunction due to redundant monitoring. The limit value for electrical voltage has not been attained. | 1 | Network |
| U300019 | The control unit has a malfunction due to redundant monitoring. The limit value for current has been exceeded. | 1 | Network |
| U300042 | The control unit has a malfunction due to redundant monitoring. There is a general memory error. | 1 | Network |
| U300043 | The control unit has a malfunction due to redundant monitoring. There is an error in the additional memory. | 1 | Network |
| U300044 | Memory: RAM check failed | 3 | Network |
| U300045 | NVRAM Error | 1 | Network |
| U300046 | Control Module | 1 | Network |
| Code | Description | Brands | System |
|---|---|---|---|
| U2E07FF | Network: External: FW_Scl_GW_AS_Actv_Ctrl_Stat_Invalid | 1 | Network |
| U2E14FF | Network: External: FW_ComScl_ESP_EDIFF_Rs_Timeout | 1 | Network |
| U300000 | Monitoring level 2 MU_Error_Md | 3 | Network |
| U300001 | If the customer returns repeatedly to the workshop with the DTC SRS- set, this may indicate that the battery voltage is poor | 3 | Network |
| U300002 | software error in errorhandler (only development) | 2 | Network |
| U300004 | The control unit has a malfunction due to redundant monitoring. There is an internal fault. | 2 | Network |
| U300005 | Lockstep fault | 2 | Network |
| U300006 | If DTC FSM- is stored, prioritise its fault tracing | 3 | Network |
| U300016 | The control unit has a malfunction due to redundant monitoring. The limit value for electrical voltage has not been attained. | 1 | Network |
| U300019 | The control unit has a malfunction due to redundant monitoring. The limit value for current has been exceeded. | 1 | Network |
| U300042 | The control unit has a malfunction due to redundant monitoring. There is a general memory error. | 1 | Network |
| U300043 | The control unit has a malfunction due to redundant monitoring. There is an error in the additional memory. | 1 | Network |
| U300044 | Memory: RAM check failed | 3 | Network |
| U300045 | NVRAM Error | 1 | Network |
| U300046 | Control Module | 1 | Network |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.