Results for “P065”
Fault codes 56
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P065141 | Der Ausgang 2 für Referenzspannung der Sensoren hat einen elektrischen Fehler oder Unterbrechung. Es liegt ein allgemeiner Prüfsummenfehler vor. | 1 | Powertrain |
| P065192 | Output 2 for the reference voltage of the sensors has an electrical fault or an open circuit. The function or the instruction is faulty. | 1 | Powertrain |
| P065198 | Der Ausgang 2 der Referenzspannung für Sensoren hat einen elektrischen Fehler oder Unterbrechung. Die Komponente oder das System hat Übertemperatur. | 2 | Powertrain |
| P0651A2 | Output 2 for the reference voltage of the sensors has an electrical fault or an open circuit. The system voltage is too low | 1 | Powertrain |
| P0651A3 | Output 2 for the reference voltage of the sensors has an electrical fault or an open circuit. The system voltage is too high | 1 | Powertrain |
| P065200 | Sensor Reference Voltage 'B' Circuit Low | 5 | Powertrain |
| P065211 | Output 2 for the reference voltage of the sensors has a short circuit to ground- There is a short circuit to ground. | 3 | Powertrain |
| P065300 | Output 2 for the reference voltage of the sensors has a short circuit to positive. | 4 | Powertrain |
| P065312 | Output 2 for the reference voltage of the sensors has a short circuit to positive- There is a short circuit to positive. | 2 | Powertrain |
| P065400 | The output signal for engine speed has an electrical fault or open circuit. | 2 | Powertrain |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P065413 | The output signal for engine speed has an electrical fault or open circuit. There is an open circuit. | 2 | Powertrain |
| P065600 | Fuel level signal sent by the cluster on CAN is not valid missing | 1 | Powertrain |
| P065700 | The power supply of the actuators has an electrical fault or an open circuit | 2 | Powertrain |
| P065701 | The power supply of the actuators has an electrical fault or an open circuit. General Electrical Failure. | 1 | Powertrain |
| P065704 | The power supply of the actuators has an electrical fault or an open circuit. System Internal Failure | 1 | Powertrain |
| P065711 | Die Stromversorgung der Aktuatoren hat Funktionsstörung. Es liegt ein Kurzschluss nach Masse vor. | 1 | Powertrain |
| P065712 | Die Stromversorgung der Aktuatoren hat Funktionsstörung. Es liegt ein Kurzschluss nach Plus vor. | 1 | Powertrain |
| P065713 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Open | 1 | Powertrain |
| P065716 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Voltage Below | 1 | Powertrain |
| P065717 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Voltage Above | 1 | Powertrain |
| P06571C | The power supply of the actuators has an electrical fault or an open circuit. The voltage value is outside the permissible range. | 1 | Powertrain |
| P06571E | The power supply of the actuators has an electrical fault or an open circuit. Circuit Resistance Out of Range | 1 | Powertrain |
| P065753 | The power supply of the actuators has an electrical fault or an open circuit. The component is deactivated. | 1 | Powertrain |
| P065800 | H-Bridge Supply Voltage out of range low | 2 | Powertrain |
| P065900 | H-Bridge Supply Voltage out of range high | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P065413 | The output signal for engine speed has an electrical fault or open circuit. There is an open circuit. | 2 | Powertrain |
| P065600 | Fuel level signal sent by the cluster on CAN is not valid missing | 1 | Powertrain |
| P065700 | The power supply of the actuators has an electrical fault or an open circuit | 2 | Powertrain |
| P065701 | The power supply of the actuators has an electrical fault or an open circuit. General Electrical Failure. | 1 | Powertrain |
| P065704 | The power supply of the actuators has an electrical fault or an open circuit. System Internal Failure | 1 | Powertrain |
| P065711 | Die Stromversorgung der Aktuatoren hat Funktionsstörung. Es liegt ein Kurzschluss nach Masse vor. | 1 | Powertrain |
| P065712 | Die Stromversorgung der Aktuatoren hat Funktionsstörung. Es liegt ein Kurzschluss nach Plus vor. | 1 | Powertrain |
| P065713 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Open | 1 | Powertrain |
| P065716 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Voltage Below | 1 | Powertrain |
| P065717 | The power supply of the actuators has an electrical fault or an open circuit. Circuit Voltage Above | 1 | Powertrain |
| P06571C | The power supply of the actuators has an electrical fault or an open circuit. The voltage value is outside the permissible range. | 1 | Powertrain |
| P06571E | The power supply of the actuators has an electrical fault or an open circuit. Circuit Resistance Out of Range | 1 | Powertrain |
| P065753 | The power supply of the actuators has an electrical fault or an open circuit. The component is deactivated. | 1 | Powertrain |
| P065800 | H-Bridge Supply Voltage out of range low | 2 | Powertrain |
| P065900 | H-Bridge Supply Voltage out of range high | 1 | Powertrain |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.