Fault codes 32,087
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| P0B7800 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0B7816 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a malfunction. Circuit Voltage Below Threshold. | 1 | Powertrain |
| P0B7817 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a malfunction. Circuit Voltage Above Threshold. | 1 | Powertrain |
| P0B7900 | Sensor M for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0B7D00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0B7E00 | Sensor N for the battery voltage of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0BBE00 | The cell voltages in the hybrid/high-voltage battery module are different. | 1 | Powertrain |
| P0BBE29 | The cell voltages in the hybrid/high-voltage battery module are different. Signal Invalid. | 1 | Powertrain |
| P0BBEA1 | The cell voltages in the hybrid/high-voltage battery module are different. System Voltage. | 1 | Powertrain |
| P0BC000 | BMS fan supply voltage Low | 1 | Powertrain |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| P0BC100 | BMS fan supply voltage High | 1 | Powertrain |
| P0BC201 | Hybrid/EV Battery Temperature Sensor 'E' Circuit. General Electrical Failure. | 1 | Powertrain |
| P0BC300 | Temperature sensor E of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0BC400 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0BD111 | Der Temperatursensor 2 des Wechselrichters 'Elektrische Maschine A' hat einen elektrischen Fehler. Es liegt ein Kurzschluss nach Masse vor. | 1 | Powertrain |
| P0BD112 | Temperature sensor C of power inverter 'Electric machine' has an electrical fault. There is a short circuit to positive. | 1 | Powertrain |
| P0BD113 | Temperature sensor 2 of the inverter 'Electric machine A' has an electrical fault. Circuit Open | 1 | Powertrain |
| P0BD127 | Temperature sensor C of power inverter 'Electric machine' has an electrical fault. The signal change rate is above the permissible limit value. | 1 | Powertrain |
| P0BD185 | Inverter Temperature Sensor BL Out of Range High | 1 | Powertrain |
| P0BD216 | Temperature sensor C of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P0BD228 | Temperature sensor 2 of inverter 'Electric machine A' has a malfunction. Signal Bias Level Out of Range/ Zero Adjustment Failure | 1 | Powertrain |
| P0BD22A | Temperature sensor 2 of inverter 'Electric machine A' has a malfunction. Signal Stuck In Range | 1 | Powertrain |
| P0BD296 | Temperature sensor C of power inverter 'Electric machine' has a malfunction. There is an internal component fault. | 1 | Powertrain |
| P0BD300 | Diagnosis to detect signal range check low at signal tSnsrPwrModlPha2Hs. | 1 | Powertrain |
| P0BD400 | Diagnosis to detect signal range check high at signal tSnsrPwrModlPha2Hs. | 1 | Powertrain |
| Code | Description | Brands | System |
|---|---|---|---|
| P0BC100 | BMS fan supply voltage High | 1 | Powertrain |
| P0BC201 | Hybrid/EV Battery Temperature Sensor 'E' Circuit. General Electrical Failure. | 1 | Powertrain |
| P0BC300 | Temperature sensor E of the hybrid/high-voltage battery has a malfunction. | 1 | Powertrain |
| P0BC400 | Temperature sensor E of the hybrid/high-voltage battery has a short circuit to ground. | 1 | Powertrain |
| P0BD111 | Der Temperatursensor 2 des Wechselrichters 'Elektrische Maschine A' hat einen elektrischen Fehler. Es liegt ein Kurzschluss nach Masse vor. | 1 | Powertrain |
| P0BD112 | Temperature sensor C of power inverter 'Electric machine' has an electrical fault. There is a short circuit to positive. | 1 | Powertrain |
| P0BD113 | Temperature sensor 2 of the inverter 'Electric machine A' has an electrical fault. Circuit Open | 1 | Powertrain |
| P0BD127 | Temperature sensor C of power inverter 'Electric machine' has an electrical fault. The signal change rate is above the permissible limit value. | 1 | Powertrain |
| P0BD185 | Inverter Temperature Sensor BL Out of Range High | 1 | Powertrain |
| P0BD216 | Temperature sensor C of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained. | 1 | Powertrain |
| P0BD228 | Temperature sensor 2 of inverter 'Electric machine A' has a malfunction. Signal Bias Level Out of Range/ Zero Adjustment Failure | 1 | Powertrain |
| P0BD22A | Temperature sensor 2 of inverter 'Electric machine A' has a malfunction. Signal Stuck In Range | 1 | Powertrain |
| P0BD296 | Temperature sensor C of power inverter 'Electric machine' has a malfunction. There is an internal component fault. | 1 | Powertrain |
| P0BD300 | Diagnosis to detect signal range check low at signal tSnsrPwrModlPha2Hs. | 1 | Powertrain |
| P0BD400 | Diagnosis to detect signal range check high at signal tSnsrPwrModlPha2Hs. | 1 | Powertrain |