Fault code lookup

Results for “P”

Fault codes 32,087

Results match keywords in the stored descriptions. Codes you typed are shown first.

CodeDescriptionBrandsSystem
P0ADF00Actuation of contact 'Negative terminal' of the contactor in the high-voltage battery has a short circuit to ground.1Powertrain
P0AE000The actuation of contact 'Negative terminal' of the contactor in the high-voltage battery has a short circuit to positive.1Powertrain
P0AE14BThe switch 'Precharging' in the hybrid/high-voltage battery module has an electrical fault. There is a fault due to overtemperature.1Powertrain
P0AE200Displaycode1Powertrain
P0AE372The switch 'Precharging' in the hybrid/high-voltage battery module is jammed in the open position. The actuator does not close.1Powertrain
P0AE413The output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. There is an open circuit.1Powertrain
P0AE49FThe output for the switch 'Precharging' at battery string A of the hybrid/high-voltage battery module has an electrical fault or an open circuit. The switch is jammed closed.1Powertrain
P0AE500Pre-charge contactor HSD output over current1Powertrain
P0AE600The output for the 'Precharging' switch in the high-voltage battery module has a short circuit to ground.1Powertrain
P0AE700The output for the 'Precharging' switch in the high-voltage battery module has a short circuit to positive.1Powertrain
Show 15 more matches on this page
CodeDescriptionBrandsSystem
P0AE801Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Electrical Failure.1Powertrain
P0AE802Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Signal Failure.1Powertrain
P0AE809Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. Component Failure.1Powertrain
P0AE815Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. There is a short circuit to positive or an open circuit.1Powertrain
P0AE900Temperature sensor D of the hybrid/high-voltage battery has a malfunction.1Powertrain
P0AE984Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal below the permissible limit value.1Powertrain
P0AE985Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal above the permissible limit value.1Powertrain
P0AEA00Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground.1Powertrain
P0AEA11Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a short circuit to ground.1Powertrain
P0AED11Out-of-range high on PCB temperature sensor 21Powertrain
P0AED12Out-of-range low on PCB temperature sensor 21Powertrain
P0AED27Der Temperatursensor A des Wechselrichters 'Elektrische Maschine' hat einen elektrischen Fehler. The signal change rate is above the permissible limit value.1Powertrain
P0AED85Inverter Temperature Sensor AL Out of Range High1Powertrain
P0AEE00Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine A' hat Funktionsstörung.2Powertrain
P0AEE16Temperature sensor A of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained.1Powertrain
CodeDescriptionBrandsSystem
P0AE801Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Electrical Failure.1Powertrain
P0AE802Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Signal Failure.1Powertrain
P0AE809Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. Component Failure.1Powertrain
P0AE815Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. There is a short circuit to positive or an open circuit.1Powertrain
P0AE900Temperature sensor D of the hybrid/high-voltage battery has a malfunction.1Powertrain
P0AE984Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal below the permissible limit value.1Powertrain
P0AE985Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal above the permissible limit value.1Powertrain
P0AEA00Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground.1Powertrain
P0AEA11Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a short circuit to ground.1Powertrain
P0AED11Out-of-range high on PCB temperature sensor 21Powertrain
P0AED12Out-of-range low on PCB temperature sensor 21Powertrain
P0AED27Der Temperatursensor A des Wechselrichters 'Elektrische Maschine' hat einen elektrischen Fehler. The signal change rate is above the permissible limit value.1Powertrain
P0AED85Inverter Temperature Sensor AL Out of Range High1Powertrain
P0AEE00Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine A' hat Funktionsstörung.2Powertrain
P0AEE16Temperature sensor A of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained.1Powertrain
Advanced: scanner vehicle and live-data matches

Vehicles 0

No matching vehicles.

Live data 0

No matching live-data parameters.

These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.

OpenDTC - independent fault code reference