Fault code lookup

Results for “P”

Fault codes 32,087

Results match keywords in the stored descriptions. Codes you typed are shown first.

CodeDescriptionBrandsSystem
P0AA314The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. There is a short circuit to ground or an open circuit.1Powertrain
P0AA316The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. The limit value for electrical voltage has not been attained.1Powertrain
P0AA317The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. The limit value for electrical voltage has been exceeded.1Powertrain
P0AA31CThe contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. Circuit Voltage Out of Range.1Powertrain
P0AA372The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. Actuator Stuck Open.1Powertrain
P0AA373The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. Actuator Stuck Closed.1Powertrain
P0AA374The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. Actuator Slipping.1Powertrain
P0AA385The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. There is a signal above the permissible limit value.1Powertrain
P0AA386The contact 'Negative terminal' of the contactor in the hybrid/high-voltage battery has an electrical fault. Signal Invalid.1Powertrain
P0AA400Displaycode1Powertrain
Show 15 more matches on this page
CodeDescriptionBrandsSystem
P0AA49FThe contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. The switch is jammed closed.1Powertrain
P0AA61AThere is an insulation fault in the hybrid/high-voltage on-board electrical system. Circuit Resistance Below Threshold.1Powertrain
P0AA61EHybrid Battery Voltage System Isolation Fault. circuit resistance out of range1Powertrain
P0AA649There is an insulation fault in the hybrid/high-voltage on-board electrical system. There is an internal electrical fault.1Powertrain
P0AA700Hybrid Battery Voltage Isolation Sensor Circuit1Powertrain
P0AA703IMD isolation measure path stuck1Powertrain
P0AA704Hybrid/EV Battery Voltage Isolation Sensor Circuit1Powertrain
P0AA706The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Algorithm Based Failure.1Powertrain
P0AA707IMD isolation measure path stuck1Powertrain
P0AA708The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Bus Signal / Message Failure.1Powertrain
P0AA709The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Component Failure.1Powertrain
P0AA716The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Below Threshold.1Powertrain
P0AA717The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Above Threshold.1Powertrain
P0AA71CHybrid Battery Voltage Isolation Sensor Circuit. circuit voltage out of range1Powertrain
P0AA71EThe ohmmeter for isolation resistance in the high-voltage battery module has an electrical fault.1Powertrain
CodeDescriptionBrandsSystem
P0AA49FThe contact 'Negative terminal' of contactor A in the high-voltage battery is jammed closed. The switch is jammed closed.1Powertrain
P0AA61AThere is an insulation fault in the hybrid/high-voltage on-board electrical system. Circuit Resistance Below Threshold.1Powertrain
P0AA61EHybrid Battery Voltage System Isolation Fault. circuit resistance out of range1Powertrain
P0AA649There is an insulation fault in the hybrid/high-voltage on-board electrical system. There is an internal electrical fault.1Powertrain
P0AA700Hybrid Battery Voltage Isolation Sensor Circuit1Powertrain
P0AA703IMD isolation measure path stuck1Powertrain
P0AA704Hybrid/EV Battery Voltage Isolation Sensor Circuit1Powertrain
P0AA706The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Algorithm Based Failure.1Powertrain
P0AA707IMD isolation measure path stuck1Powertrain
P0AA708The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Bus Signal / Message Failure.1Powertrain
P0AA709The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Component Failure.1Powertrain
P0AA716The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Below Threshold.1Powertrain
P0AA717The ohmmeter for the isolation resistance in the hybrid/high-voltage battery module has an electrical fault. Circuit Voltage Above Threshold.1Powertrain
P0AA71CHybrid Battery Voltage Isolation Sensor Circuit. circuit voltage out of range1Powertrain
P0AA71EThe ohmmeter for isolation resistance in the high-voltage battery module has an electrical fault.1Powertrain
Advanced: scanner vehicle and live-data matches

Vehicles 0

No matching vehicles.

Live data 0

No matching live-data parameters.

These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.

OpenDTC - independent fault code reference