Results for “U195”
Fault codes 27
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| U1950 | UBP Comm Bus Fault - DSM,or UBP Comm Bus Fault - VSM,or UBP Comm Bus Fault - Instr Clstr | 7 | Network |
| U1951 | Lost Communication with Seat Memory Control Module | 8 | Network |
| U1952 | Broms 1 CRC-fel - signal ogiltig | 7 | Network |
| U1953 | Rem 1 berichttellerfout - signaal ongeldig | 2 | Network |
| U1954 | No description available | 2 | Network |
| U1956 | Rem 3 CRC of berichttellerfout - signaal ongeldig | 1 | Network |
| U1957 | BRAKE3 berichttellerfout | 1 | Network |
| U1958 | No description available | 1 | Network |
| U1959 | Fren 3 tork istek sinyali mevcut değil | 1 | Network |
| U1950F0 | Low Confidence - CHG - Charger internal problem detected | 1 | Network |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| U1950F1 | Charger internal problem detected | 1 | Network |
| U1951F0 | Low Confidence - CHG - Charger internal problem detected | 1 | Network |
| U1951F1 | Charger internal problem detected | 1 | Network |
| U1952F0 | Low Confidence - CHG - Charger internal problem detected | 1 | Network |
| U1952F1 | Charger internal problem detected | 1 | Network |
| U195AF0 | Low Confidence - CHG - Charger voltage sensing error detected | 1 | Network |
| U195AF1 | Charger voltage sensing error detected | 1 | Network |
| U195BF0 | Low Confidence - CHG - Proximity sensing error detected | 1 | Network |
| U195BF1 | Charger - Proximity sensing error detected | 1 | Network |
| U195CF0 | Low Confidence - CHG | 1 | Network |
| U195CF1 | Low Confidence - CHG | 1 | Network |
| U195DF0 | Low Confidence - CHG | 1 | Network |
| U195DF1 | Low Confidence - CHG | 1 | Network |
| U195E00 | Water Control Unit - Error Value VDSO_Vx3d | 1 | Network |
| U195EF1 | Charger - Internal temperature sensing error detected | 1 | Network |
| Code | Description | Brands | System |
|---|---|---|---|
| U1950F1 | Charger internal problem detected | 1 | Network |
| U1951F0 | Low Confidence - CHG - Charger internal problem detected | 1 | Network |
| U1951F1 | Charger internal problem detected | 1 | Network |
| U1952F0 | Low Confidence - CHG - Charger internal problem detected | 1 | Network |
| U1952F1 | Charger internal problem detected | 1 | Network |
| U195AF0 | Low Confidence - CHG - Charger voltage sensing error detected | 1 | Network |
| U195AF1 | Charger voltage sensing error detected | 1 | Network |
| U195BF0 | Low Confidence - CHG - Proximity sensing error detected | 1 | Network |
| U195BF1 | Charger - Proximity sensing error detected | 1 | Network |
| U195CF0 | Low Confidence - CHG | 1 | Network |
| U195CF1 | Low Confidence - CHG | 1 | Network |
| U195DF0 | Low Confidence - CHG | 1 | Network |
| U195DF1 | Low Confidence - CHG | 1 | Network |
| U195E00 | Water Control Unit - Error Value VDSO_Vx3d | 1 | Network |
| U195EF1 | Charger - Internal temperature sensing error detected | 1 | Network |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.