Results for “U”
Fault codes 7,936
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| U3DD800 | Phase Overcurrent detected during standstill | 1 | Network |
| U3DF000 | HV lock status | 1 | Network |
| U3DF100 | General Vdd5 under voltage monitoring error. At least one Ls-ASIC report VDD5_ERR_UV bit set in error register 2 | 1 | Network |
| U3DF500 | Rotor temperature from model based on sensor less physical model 2 Stator temperature is implausible. | 1 | Network |
| U3DFC00 | UART communication failure during Idle(VDSS) mode request. | 1 | Network |
| U3E0100 | mechanical of clutch actuator not plausible | 1 | Network |
| U3E1C00 | frequency monitoring of latency fault check VDS (BIST8) over all Ls Asics | 1 | Network |
| U3E1E00 | frequency monitoring of latency fault check VDS (BIST8) over all Hs Asics | 1 | Network |
| U3E2000 | frequency monitoring of latency fault check VDS external circuit (BIST10) over all Ls Asics | 1 | Network |
| U3E2500 | Frequency monitoring of latency fault check VDSS upper threshold (BIST4) and VDSS lower threshold (BIST5) over all Asics | 1 | Network |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| U3E2B00 | frequency monitoring of latency fault check SCP Gate1-4 (BIST6) over all Ls Asics | 1 | Network |
| U3E2D00 | frequency monitoring of latency fault check SCP Gate1-4 (BIST6) over all Hs Asics | 1 | Network |
| U3E4500 | combined error for CAN and DCDC-GND loss | 1 | Network |
| U3E5B00 | Sensorless Control Mode request status | 1 | Network |
| U3E6C00 | Performance issue of cluth position sensor e.g. due to low supply voltage | 1 | Network |
| U3E7200 | Cluth actuator phase current at standstill of actuator diagnosis | 1 | Network |
| U3E7300 | Timeout error for CAN message PT4_VEPM_Rq_ST3 (contains energy request for 48V battery) | 1 | Network |
| U3E7400 | Actuator phase overcurrent by DS-ADC detected | 1 | Network |
| U3E7600 | Timeout Error CAN-Botschaft CPC_ENERGY_COM_Container1_ST3_PT4_PTCoor4_ST3 | 1 | Network |
| U3E7700 | Clutch actuator DC overcurrent detected | 1 | Network |
| U3E7800 | Overvoltage of B6 bridge supply voltage (12V) of the cluth actuator | 1 | Network |
| U3E7900 | Cluth actuator bridge driver overtemperature detected. | 1 | Network |
| U3E7A00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_DI_OdoSpeedometer_ST3 (contains odometer value) | 1 | Network |
| U3E7B00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_DIAG_Stat_ST3 (contains external tester present information) | 1 | Network |
| U3E7D00 | timeout Error for CAN message CPC_ENERGY_GW_Container1_ST3_Ign_Stat_ST3 | 1 | Network |
| Code | Description | Brands | System |
|---|---|---|---|
| U3E2B00 | frequency monitoring of latency fault check SCP Gate1-4 (BIST6) over all Ls Asics | 1 | Network |
| U3E2D00 | frequency monitoring of latency fault check SCP Gate1-4 (BIST6) over all Hs Asics | 1 | Network |
| U3E4500 | combined error for CAN and DCDC-GND loss | 1 | Network |
| U3E5B00 | Sensorless Control Mode request status | 1 | Network |
| U3E6C00 | Performance issue of cluth position sensor e.g. due to low supply voltage | 1 | Network |
| U3E7200 | Cluth actuator phase current at standstill of actuator diagnosis | 1 | Network |
| U3E7300 | Timeout error for CAN message PT4_VEPM_Rq_ST3 (contains energy request for 48V battery) | 1 | Network |
| U3E7400 | Actuator phase overcurrent by DS-ADC detected | 1 | Network |
| U3E7600 | Timeout Error CAN-Botschaft CPC_ENERGY_COM_Container1_ST3_PT4_PTCoor4_ST3 | 1 | Network |
| U3E7700 | Clutch actuator DC overcurrent detected | 1 | Network |
| U3E7800 | Overvoltage of B6 bridge supply voltage (12V) of the cluth actuator | 1 | Network |
| U3E7900 | Cluth actuator bridge driver overtemperature detected. | 1 | Network |
| U3E7A00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_DI_OdoSpeedometer_ST3 (contains odometer value) | 1 | Network |
| U3E7B00 | Timeout error for CAN message CPC_ENERGY_GW_Container1_ST3_DIAG_Stat_ST3 (contains external tester present information) | 1 | Network |
| U3E7D00 | timeout Error for CAN message CPC_ENERGY_GW_Container1_ST3_Ign_Stat_ST3 | 1 | Network |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.