Results for “U”
Fault codes 7,936
Results match keywords in the stored descriptions. Codes you typed are shown first.
| Code | Description | Brands | System |
|---|---|---|---|
| U060C12 | Communication with boost pressure sensor 2 has a malfunction. There is a short circuit to positive. | 1 | Network |
| U060CEE | There is an internal control unit fault in the central processing unit.UART Communication error | 1 | Network |
| U061111 | Communication with intake air temperature sensor 1 (cylinder bank 1) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U061112 | Communication with intake air temperature sensor 1 (cylinder bank 1) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U061200 | Internal error in C3I data | 1 | Network |
| U061211 | Communication with intake air temperature sensor 1 (cylinder bank 2) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U061212 | Communication with intake air temperature sensor 1 (cylinder bank 2) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U062011 | Communication with exhaust gas temperature sensor 2 (cylinder bank 1) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U062015 | Communication with exhaust gas temperature sensor 2 (cylinder bank 1) has a malfunction. There is a short circuit to positive or an open circuit. | 1 | Network |
| U062211 | Communication with exhaust gas temperature sensor 2 (cylinder bank 2) has a malfunction. There is a short circuit to ground. | 1 | Network |
Show 15 more matches on this page
| Code | Description | Brands | System |
|---|---|---|---|
| U062215 | Communication with exhaust gas temperature sensor 2 (cylinder bank 2) has a malfunction. There is a short circuit to positive or an open circuit. | 1 | Network |
| U063000 | Variant coding is not done | 1 | Network |
| U063100 | Variant coding writing error | 1 | Network |
| U063300 | Immobilizer fault (refer to immobilizer section) | 1 | Network |
| U068411 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 1) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U068412 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 1) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U068611 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 2) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U068612 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 2) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U069887 | Communication with coolant pump 2 of the low-temperature circuit has a malfunction. The message is missing. | 1 | Network |
| U0698E0 | Communication with coolant pump 2 of the low-temperature circuit has a malfunction. | 1 | Network |
| U077C31 | Off-Board Charger Control Module - Chademo Can Timeout | 1 | Network |
| U077C64 | Off-Board Charger Control Module - CST received with Fault/Error bits set | 1 | Network |
| U077C81 | Off-Board Charger Control Module - Timeout in Chademo Lock | 1 | Network |
| U077C86 | Off-Board Charger Control Module - Fast Open by EVSE Chademo | 1 | Network |
| U077C87 | Off-Board Charger Control Module - Protocol Procedure time out | 1 | Network |
| Code | Description | Brands | System |
|---|---|---|---|
| U062215 | Communication with exhaust gas temperature sensor 2 (cylinder bank 2) has a malfunction. There is a short circuit to positive or an open circuit. | 1 | Network |
| U063000 | Variant coding is not done | 1 | Network |
| U063100 | Variant coding writing error | 1 | Network |
| U063300 | Immobilizer fault (refer to immobilizer section) | 1 | Network |
| U068411 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 1) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U068412 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 1) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U068611 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 2) has a malfunction. There is a short circuit to ground. | 1 | Network |
| U068612 | Communication with temperature sensor 1 'Catalytic converter' (cylinder bank 2) has a malfunction. There is a short circuit to positive. | 1 | Network |
| U069887 | Communication with coolant pump 2 of the low-temperature circuit has a malfunction. The message is missing. | 1 | Network |
| U0698E0 | Communication with coolant pump 2 of the low-temperature circuit has a malfunction. | 1 | Network |
| U077C31 | Off-Board Charger Control Module - Chademo Can Timeout | 1 | Network |
| U077C64 | Off-Board Charger Control Module - CST received with Fault/Error bits set | 1 | Network |
| U077C81 | Off-Board Charger Control Module - Timeout in Chademo Lock | 1 | Network |
| U077C86 | Off-Board Charger Control Module - Fast Open by EVSE Chademo | 1 | Network |
| U077C87 | Off-Board Charger Control Module - Protocol Procedure time out | 1 | Network |
Advanced: scanner vehicle and live-data matches
Vehicles 0
No matching vehicles.
Live data 0
No matching live-data parameters.
These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.