Fault code lookup

Results for “P”

Fault codes 32,087

Results match keywords in the stored descriptions. Codes you typed are shown first.

CodeDescriptionBrandsSystem
P1AE6FBDas Widerstandsmessgerät für Isolationswiderstand im Hybrid/Hochvoltbatteriemodul hat einen elektrischen Fehler. MonrImdCtl_PNetToCanMsgBox1Powertrain
P1AE6FCDas Widerstandsmessgerät für Isolationswiderstand im Hybrid/Hochvoltbatteriemodul hat einen elektrischen Fehler. MonrImdCtl_HvcToImd1Powertrain
P1AE6FDDas Widerstandsmessgerät für Isolationswiderstand im Hybrid/Hochvoltbatteriemodul hat einen elektrischen Fehler. MonrImdCtl_ImdReqToActual1Powertrain
P1AE6FFDas Widerstandsmessgerät für Isolationswiderstand im Hybrid/Hochvoltbatteriemodul hat einen elektrischen Fehler. GND Path HVC21Powertrain
P1AE71ABattery Energy Control Module Hybrid Battery Voltage System Isolation Circuit. circuit resistance below threshold1Powertrain
P1AED85Sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine A' has a malfunction. There is a signal above the permissible limit value.1Powertrain
P1AFF12Das Steuergerät 'Elektrische Maschine A' hat eine angeforderte Systemabschaltung durchgeführt. Es liegt ein Kurzschluss nach Plus vor. Short circuit to battery error1Powertrain
P1AFF13Das Steuergerät 'Elektrische Maschine A' hat eine angeforderte Systemabschaltung durchgeführt. Es liegt eine Unterbrechung vor. No load error1Powertrain
P1AFF98Das Steuergerät 'Elektrische Maschine A' hat eine angeforderte Systemabschaltung durchgeführt. Die Komponente oder das System hat Übertemperatur. Over temperature error for HVBRly1Powertrain
P1B0146ASIC internal reset event during normal operation. At least one ASIC lost the configuration data due to ASIC internal reset1Powertrain
Show 15 more matches on this page
CodeDescriptionBrandsSystem
P1B014BGeneral overheat temperature monitoring error. At least one ASIC report TEMP_ERR bit set in error register 21Powertrain
P1B0196General none expected NABE error of at least on Hs-ASIC without any fault reason detected1Powertrain
P1B0197General none expected NABE error of at least on Ls-ASIC without any fault reason detected1Powertrain
P1B01FAGeneral none expected NERR1 error of at least on Hs-ASIC without any fault reason detected1Powertrain
P1B01FBGeneral none expected NERR1 error of at least on Ls-ASIC without any fault reason detected1Powertrain
P1B01FDAn internal fault has occurred in the logic module of control unit 'Electric machine A'.1Powertrain
P1B01FFAn internal fault has occurred in the logic module of control unit 'Electric machine A'.1Powertrain
P1B0973Contact 'Positive pole' of the contactor in control unit 'DC safety system' has a malfunction. Actuator Stuck Closed1Powertrain
P1B0A73Contact 'Negative pole' of the contactor in control unit 'DC safety system' has a malfunction. Actuator Stuck Closed1Powertrain
P1B0C00The calibration from the High-Voltage sensor in control unit 'Electric machine A' is faulty.1Powertrain
P1B0E63The precharging time of control unit 'DC safety system' is too long. Circuit / Component Protection Time-Out1Powertrain
P1B1001The power supply at control unit 'DC safety system' has a malfunction. General Electrical Failure1Powertrain
P1B1100No description available1Powertrain
P1B164BThe output of the electric machine is reduced. There is a fault due to overtemperature.1Powertrain
P1B1700The overload protection of switch 'Precharging' of the high-voltage battery is active.2Powertrain
CodeDescriptionBrandsSystem
P1B014BGeneral overheat temperature monitoring error. At least one ASIC report TEMP_ERR bit set in error register 21Powertrain
P1B0196General none expected NABE error of at least on Hs-ASIC without any fault reason detected1Powertrain
P1B0197General none expected NABE error of at least on Ls-ASIC without any fault reason detected1Powertrain
P1B01FAGeneral none expected NERR1 error of at least on Hs-ASIC without any fault reason detected1Powertrain
P1B01FBGeneral none expected NERR1 error of at least on Ls-ASIC without any fault reason detected1Powertrain
P1B01FDAn internal fault has occurred in the logic module of control unit 'Electric machine A'.1Powertrain
P1B01FFAn internal fault has occurred in the logic module of control unit 'Electric machine A'.1Powertrain
P1B0973Contact 'Positive pole' of the contactor in control unit 'DC safety system' has a malfunction. Actuator Stuck Closed1Powertrain
P1B0A73Contact 'Negative pole' of the contactor in control unit 'DC safety system' has a malfunction. Actuator Stuck Closed1Powertrain
P1B0C00The calibration from the High-Voltage sensor in control unit 'Electric machine A' is faulty.1Powertrain
P1B0E63The precharging time of control unit 'DC safety system' is too long. Circuit / Component Protection Time-Out1Powertrain
P1B1001The power supply at control unit 'DC safety system' has a malfunction. General Electrical Failure1Powertrain
P1B1100No description available1Powertrain
P1B164BThe output of the electric machine is reduced. There is a fault due to overtemperature.1Powertrain
P1B1700The overload protection of switch 'Precharging' of the high-voltage battery is active.2Powertrain
Advanced: scanner vehicle and live-data matches

Vehicles 0

No matching vehicles.

Live data 0

No matching live-data parameters.

These tables come from diagnostic data. They are useful for advanced users and can be ignored for a normal code lookup.

OpenDTC - independent fault code reference