Fault code lookup

MAYBACH fault codes

Coverage shown is Mercedes-Benz data: 20,291 codes · 1,724 vehicle records · 258 ECU records · 56,350 live-data parameters.

MAYBACH shares fault-code data with Mercedes-Benz. Data may not cover MAYBACH-specific systems.

Browse Mercedes-Benz codes

Search these codes

Codes 20,291

CodeDescriptionBrandsSystem
U1DD147Range of development fault memory There is a runtime error.1Network
U1DD148Range of development fault memory There is an error in the control memory.1Network
U1DD149Range of development fault memory There is an internal electrical fault.1Network
U1DD150Range of development fault memory1Network
U1DD151Range of development fault memory The component is not programmed.1Network
U1DD152Range of development fault memory The component has not been put into operation.1Network
U1DD153Range of development fault memory The component is deactivated.1Network
U1DD154Range of development fault memory Calibration is missing.1Network
U1DD155Range of development fault memory The component is not configured.1Network
U1DD156Range of development fault memory An incorrect or incompatible configuration was detected.1Network
U1DD157Range of development fault memory Incorrect or incompatible software modules were detected.1Network
U1DD158Range of development fault memory1Network
U1DD159Range of development fault memory1Network
U1DD160Range of development fault memory1Network
U1DD185Cicruit Breaker Control Error - ADuC CB Off1Network
U1DD186Circuit Breaker Damaged - Stuck Open Warning1Network
U1DD187Circuit Breaker Damaged - Stuck Close1Network
U1DD188CCB is aged1Network
U1DD198Range of development fault memory The component or the system has overtemperature.1Network
U1DD199Range of development fault memory1Network
U1DD2No description available1Network
U1DD201Range of development fault memory There is a general electrical fault.1Network
U1DD202Range of development fault memory There is a general signal fault.1Network
U1DD210Range of development fault memory1Network
U1DD211Range of development fault memory There is a short circuit to ground.1Network
U1DD212Range of development fault memory There is a short circuit to positive.1Network
U1DD213energy request from the vehicle is not processed for S1 closure, but is converted to DCDCOnly mode request due to Low SOC condition1Network
U1DD214CAN wakeup is disabled due to minimum cell voltage1Network
U1DD225Range of development fault memory There is a faulty signal waveform.1Network
U1DD226Range of development fault memory The signal change rate is below the permissible limit value.1Network
U1DD228T30 and T31 temperature differ over 10C1Network
U1DD229Range of development fault memory There is an invalid signal.1Network
U1DD230Range of development fault memory1Network
U1DD231Range of development fault memory The signal is not present.1Network
U1DD232Range of development fault memory The off-time of the signal frequency is too short.1Network
U1DD233Range of development fault memory The off-time of the signal frequency is too long.1Network
U1DD234No description available1Network
U1DD235Balancing started for no reason1Network
U1DD236If input temp invalid for actual capacity determination1Network
U1DD237If the aging factor (AF) has an out of range fault1Network
U1DD238CAN Timeout Error1Network
U1DD239CAN Bus Off Error1Network
U1DD240Watchdog Error1Network
U1DD241ADuC_SPI Timeout Error1Network
U1DD242UART Timeout Error1Network
U1DD243E2E Ignition Switch State error1Network
U1DD244E2E Vehicle Stop State error1Network
U1DD245Shunt Temperature Implausible1Network
U1DD246ADuC Watchdog CB Off Error1Network
U1DD247CB Charge Pump Voltage too low1Network

Some brand data is extracted from diagnostic files and may contain manufacturer-specific wording. General SAE J2012 descriptions are used where available.