CodeDescriptionBrandsSystem
P0D2609The precharging time for the on-board charger is too long. There is a component fault.1Powertrain
P0D2664The precharging time for the on-board charger is too long. There is an implausible signal.1Powertrain
P0D2696The precharging time for the on-board charger is too long. There is an internal component fault.1Powertrain
P0D26FABattery Charger System Precharge Time Too Long - HVAC Bulk R11Powertrain
P0D26FBBattery Charger System Precharge Time Too Long - HVAC Bulk R21Powertrain
P0D2700Battery Charger Input Voltage Too Low1Powertrain
P0D2702The input voltage of the on-board charger is too low. There is a general signal fault.2Powertrain
P0D2716The input voltage of the on-board charger is too low. The limit value for electrical voltage has not been attained.1Powertrain
P0D2718The input voltage of the on-board charger is too low. The limit value for current has not been attained.1Powertrain
P0D271CThe input voltage of the on-board charger is too low. The voltage value is outside the permissible range.1Powertrain
P0D27FABattery Charger Input Voltage Too Low Phase L1/N - Development1Powertrain
P0D27FBBattery Charger Input Voltage Too Low Phase L2 - Development1Powertrain
P0D2800Battery Charger Input Voltage Too High1Powertrain
P0D2801The input voltage of the on-board charger is too high. There is a general electrical fault.2Powertrain
P0D2802The input voltage of the on-board charger is too high. There is a general signal fault.2Powertrain
P0D2812The input voltage of the on-board charger is too high. The limit value for electrical voltage has been exceeded.1Powertrain
P0D2815The input voltage of the on-board charger is too high. The voltage value is outside the permissible range.1Powertrain
P0D2A19Battery Charger Input Current Too High. Circuit Current Above Threshold1Powertrain
P0D2AFBBattery Charger 'A' Input Current Too High - R21Powertrain
P0D2AFCBattery Charger 'A' Input Current Too High - R31Powertrain
P0D2D17Sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine A' has an electrical fault. The limit value for electrical voltage has been exceeded.1Powertrain
P0D2DA3Sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine A' has an electrical fault. The system voltage is too high.1Powertrain
P0D2EOutput 5 failure10Powertrain
P0D2FDrive Motor A Inverter Voltage Sensor A Circuit Low17Powertrain
P0D30Drive Motor A Inverter Voltage Sensor A Circuit High17Powertrain
P0D33Output 10 fault10Powertrain
P0D3300DC/DC Converter Current High1Powertrain
P0D3301Overcurrent at IN48 Cell 21Powertrain
P0D3400DTC is set2Powertrain
P0D37Hybrid/EV Battery System Current High15Powertrain
P0D3700Hybrid/EV Battery System Current High1Powertrain
P0D38Battery charger 'A' input current sensor circuit9Powertrain
P0D3812The sensor 'Input current of on-board charger' has an electrical fault. There is a short circuit to positive1Powertrain
P0D3819The sensor 'Input current of on-board charger' has an electrical fault. The limit value for current has been exceeded.1Powertrain
P0D38FAThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D38FBThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D38FCThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D38FDThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D38FEThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D38FFThe sensor 'Input current of on-board charger' has an electrical fault.1Powertrain
P0D39FASensor 'Input current of on-board charger' has a malfunction.1Powertrain
P0D39FBSensor 'Input current of on-board charger' has a malfunction.1Powertrain
P0D39FCSensor 'Input current of on-board charger' has a malfunction.1Powertrain
P0D3A00Battery Charger Input Current Sensor Circuit Low1Powertrain
P0D3B00Battery Charger Input Current Sensor Circuit High1Powertrain
P0D3D00Battery Charger Input Voltage Sensor Circuit1Powertrain
P0D3D11The sensor 'Input voltage of on-board charger' has an electrical fault. There is a short circuit to ground1Powertrain
P0D3D12The sensor 'Input voltage of on-board charger' has an electrical fault. There is a short circuit to positive1Powertrain
P0D3DA2The sensor 'Input voltage of on-board charger' has an electrical fault. The system voltage is too low1Powertrain
P0D3DA3The sensor 'Input voltage of on-board charger' has an electrical fault. The system voltage is too high.1Powertrain