Mercedes-Benz fault codes
20,291 codes · 1,724 vehicle records · 258 ECU records · 56,350 live-data parameters
Search only Mercedes-Benz codes
Codes 20,291
| Code | Description | Brands | System |
|---|---|---|---|
| P05FE71 | Radiator shutter 3 does not close. The actuator is blocked. | 1 | Powertrain |
| P05FF | Built-in System Interface (BSI) internal fault (reset the Built-in System Interface) | 14 | Powertrain |
| P05FF04 | The relationship between the brake pressure and brake pedal travel is implausible. There is an internal fault. | 1 | Powertrain |
| P05FF06 | The relationship between the brake pressure and brake pedal travel is implausible. There is an algorithm fault. | 1 | Powertrain |
| P0600 | Serial Communication Link | 39 | Powertrain |
| P060000 | Internal communication in the control unit has a malfunction. | 2 | Powertrain |
| P060002 | Communication timeout (no expected signal) | 1 | Powertrain |
| P060003 | Communication loss (no idle signal) | 1 | Powertrain |
| P060004 | Communication error | 1 | Powertrain |
| P060005 | Communication timeout (no expected signal) | 1 | Powertrain |
| P060006 | Communication loss (no idle signal) | 1 | Powertrain |
| P060007 | Communication error | 1 | Powertrain |
| P060008 | Traction net voltage from COM failure | 1 | Powertrain |
| P060009 | Communication loss (no idle signal) | 1 | Powertrain |
| P06000A | Communication fault with BPS | 1 | Powertrain |
| P06000B | Communication with CSC lost | 1 | Powertrain |
| P060026 | Too less or to much data received at UART of phase 1. Rx data evaluation for Ls- and Hs-ASIC not possible | 1 | Powertrain |
| P060027 | Too less or to much data received at UART of phase 2. Rx data evaluation for Ls- and Hs-ASIC not possible | 1 | Powertrain |
| P060049 | Serial Communication Link | 1 | Powertrain |
| P060055 | Die interne Kommunikation im Steuergerät hat Funktionsstörung. Das Bauteil ist nicht konfiguriert. | 1 | Powertrain |
| P060062 | Die interne Kommunikation im Steuergerät hat Funktionsstörung. Der Signalvergleich ist fehlerhaft. | 1 | Powertrain |
| P060068 | At least one LowSide ASIC report a UART protocol error | 1 | Powertrain |
| P060081 | At least one HighSide ASIC report a Rx message counter mismatch | 1 | Powertrain |
| P060082 | At least one LowSide ASIC report a Rx message counter mismatch | 1 | Powertrain |
| P060083 | Internal communication in the control unit has a malfunction. The checksum for the message has an incorrect value. | 1 | Powertrain |
| P060087 | Internal communication in the control unit has a malfunction. The message is missing. | 1 | Powertrain |
| P060094 | Internal communication in the control unit has a malfunction. There is an unexpected instruction. | 1 | Powertrain |
| P060096 | Die interne Kommunikation im Steuergerät hat Funktionsstörung. Es liegt ein interner Komponentenfehler vor. | 1 | Powertrain |
| P0600E4 | Internal communication in the control unit has a malfunction. CRC Payload Error von Slave und Master | 1 | Powertrain |
| P0600E5 | Internal communication in the control unit has a malfunction. IPC Error related to size of Container ID | 1 | Powertrain |
| P0600E6 | Internal communication in the control unit has a malfunction. IPC Container ID not defined | 1 | Powertrain |
| P0600E7 | Internal communication in the control unit has a malfunction. Software lockstep integration error / internal error dectected on master | 1 | Powertrain |
| P0600E8 | Software lockstep runtime error master to slave dectected on master | 1 | Powertrain |
| P0600E9 | Internal communication in the control unit has a malfunction. Software lockstep runtime error slave to master dectected on master | 1 | Powertrain |
| P0600EA | Internal communication in the control unit has a malfunction. Software lockstep end-to-end protection error dectected on master | 1 | Powertrain |
| P0600EB | Anzahl der fehlgeschlagenen Transmission an Slave versucht. | 1 | Powertrain |
| P0600F9 | Software Error in BSW (Example insufficient SW resource) | 1 | Powertrain |
| P0600FA | Serial Communication Link. FA | 1 | Powertrain |
| P0600FB | Serial Communication Link. FB | 1 | Powertrain |
| P0600FC | Internal communication in the control unit has a malfunction. Software lockstep end-to-end protection error dectected on slave | 1 | Powertrain |
| P0600FD | Internal communication in the control unit has a malfunction. IPC Security Error detected on Slave | 1 | Powertrain |
| P0600FE | Internal communication in the control unit has a malfunction. CRC Header Error from Master to Slave | 1 | Powertrain |
| P0601 | Internal Control Module Memory Check Sum Error | 41 | Powertrain |
| P060100 | Internal Control Module Memory Checksum Error | 4 | Powertrain |
| P060104 | There is an internal control unit fault affecting the calculation of the checksum. System Internal Failure | 2 | Powertrain |
| P060105 | There is an internal control unit fault affecting the calculation of the checksum. System Programming Failure | 2 | Powertrain |
| P060106 | There is an internal control unit fault affecting the calculation of the checksum. Algorithm Based Failure | 2 | Powertrain |
| P060141 | general checksum failure ECU-Memory - Check sum verification number Integrity fault | 2 | Powertrain |
| P060142 | Internal Control Module Memory Checksum Error general memory failure | 2 | Powertrain |
| P060143 | There is an internal control unit fault affecting the calculation of the checksum. Special Memory Failure | 2 | Powertrain |
Some brand data is extracted from diagnostic files and may contain manufacturer-specific wording. General SAE J2012 descriptions are used where available.