Fault code lookup

Mercedes-Benz fault codes

20,291 codes · 1,724 vehicle records · 258 ECU records · 56,350 live-data parameters

Search only Mercedes-Benz codes

Shared-name brands using this data:

Codes 20,291

CodeDescriptionBrandsSystem
U3017E1Control Module Timer/Clock Performance1Network
U3017E5The real-time internal control unit clock has a malfunction. Peripheral clock. Per PLL loss of lock1Network
U3017FAThe real-time internal control unit clock has a malfunction.1Network
U3017FBThe real-time internal control unit clock has a malfunction.1Network
U3017FFAurix (Master Controller) recovery timer fault1Network
U301DControl Module Wake-up Circuit A Performance4Network
U302083The security module of the control unit has detected a communication error - Value of Signal Protection Calculation Incorrect1Network
U303657Communication Authentication Signal Performance - Incompatible Software Component1Network
U303681Communication Authentication Signal Performance - Invalid tick count received1Network
U3242No description available3Network
U3501Control Module Input Power A Circuit Low12Network
U3505Control Module Input Power B Circuit Low12Network
U3510Control Module Missing Calibration5Network
U3511High voltage system interlock circuit 'B'5Network
U351100Interlock circuit B of the high-voltage on-board electrical system has an electrical fault.1Network
U351101High Voltage Interlock Hvac open circuit1Network
U351111High Voltage Interlock Hvac short to ground1Network
U351112High Voltage Interlock Hvac Short to battery1Network
U351113High Voltage Interlock Hvac open circuit1Network
U3511FAInterlock circuit B of the high-voltage on-board electrical system has an electrical fault. HVIL EATS Rear.1Network
U3512High voltage system interlock circuit 'B' performance5Network
U3513High voltage system interlock circuit 'B' low5Network
U3514High voltage system interlock circuit 'B' high5Network
U3515High voltage system interlock circuit 'C'4Network
U351500Interlock circuit C of the high-voltage on-board electrical system has an open circuit.1Network
U351511Interlock circuit C of the high-voltage on-board electrical system has an open circuit. There is a short circuit to ground1Network
U351512Interlock circuit C of the high-voltage on-board electrical system has an open circuit. There is a short circuit to positive.1Network
U351513Interlock circuit C of the high-voltage on-board electrical system has an open circuit. There is an open circuit.1Network
U3515FAInterlock circuit C of the high-voltage on-board electrical system has an open circuit. HVIL Service Disconnect1Network
U3516High voltage system interlock circuit 'C' performance4Network
U3517High voltage system interlock circuit 'C' low4Network
U351911Interlock circuit D of the high-voltage on-board electrical system has an electrical fault. There is a short circuit to ground.1Network
U351912Interlock circuit D of the high-voltage on-board electrical system has an electrical fault. There is a short circuit to positive.1Network
U351913Interlock circuit D of the high-voltage on-board electrical system has an electrical fault. There is an open circuit.1Network
U3519FAInterlock circuit D of the high-voltage on-board electrical system has an electrical fault. HVIL EATS Front.1Network
U357700Sensor module C of the hybrid/high-voltage battery module has a malfunction.1Network
U35774BSensor module C of the hybrid/high-voltage battery module has a malfunction. Over Temperature.1Network
U358B01Internal temperature sensor 3 of the control unit has an electrical fault. There is a general electrical fault.1Network
U358B16Control Module Internal Temperature Sensor 'C' Circuit - The limit value for electrical voltage has not been attained.1Network
U358B17Control Module Internal Temperature Sensor 'C' Circuit - The limit value for electrical voltage has been exceeded.1Network
U358BFAControl Module Internal Temperature Sensor C Circuit - There is a positive offset, Negative contactor.1Network
U358BFBControl Module Internal Temperature Sensor C Circuit - There is a negative offset, Negative contactor.1Network
U358F16No description available1Network
U358F17No description available1Network
U359116No description available1Network
U359117No description available1Network
U35D817Internal temperature sensor 4 of the control unit has an electrical fault. The limit value for electrical voltage has been exceeded.1Network
U35D8FAControl Module Internal Temperature Sensor 'D' Circuit - There is a positive offset, Positive contactor.1Network
U35D8FBControl Module Internal Temperature Sensor 'D' Circuit - There is a negative offset, Positive contactor.1Network
U365A81Vehicle Communication Bus 'L' - Invalid error for AC Temp related messages1Network

Some brand data is extracted from diagnostic files and may contain manufacturer-specific wording. General SAE J2012 descriptions are used where available.