Fault code lookup

Mercedes-Benz fault codes

20,291 codes · 1,724 vehicle records · 258 ECU records · 56,350 live-data parameters

Search only Mercedes-Benz codes

Shared-name brands using this data:

Codes 20,291

CodeDescriptionBrandsSystem
P0AE700The output for the 'Precharging' switch in the high-voltage battery module has a short circuit to positive.1Powertrain
P0AE8Hybrid Battery Temperature Sensor D Circuit24Powertrain
P0AE801Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Electrical Failure.1Powertrain
P0AE802Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. General Signal Failure.1Powertrain
P0AE809Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. Component Failure.1Powertrain
P0AE815Temperature sensor D of the hybrid/high-voltage battery has an electrical fault. There is a short circuit to positive or an open circuit.1Powertrain
P0AE9Hybrid/EV Battery Temperature Sensor D Circuit Range/Performance27Powertrain
P0AE900Temperature sensor D of the hybrid/high-voltage battery has a malfunction.1Powertrain
P0AE984Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal below the permissible limit value.1Powertrain
P0AE985Temperature sensor D of the hybrid/high-voltage battery has a malfunction. There is a signal above the permissible limit value.1Powertrain
P0AEAHybrid/EV Battery Temperature Sensor D Circuit Low27Powertrain
P0AEA00Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground.1Powertrain
P0AEA11Temperature sensor D of the hybrid/high-voltage battery has a short circuit to ground. There is a short circuit to ground.1Powertrain
P0AEBHybrid/EV Battery Temperature Sensor D Circuit High28Powertrain
P0AECHybrid Battery Temperature Sensor D Circuit Intermittent/Erratic23Powertrain
P0AED11Out-of-range high on PCB temperature sensor 21Powertrain
P0AED12Out-of-range low on PCB temperature sensor 21Powertrain
P0AED27Der Temperatursensor A des Wechselrichters 'Elektrische Maschine' hat einen elektrischen Fehler. The signal change rate is above the permissible limit value.1Powertrain
P0AED85Inverter Temperature Sensor AL Out of Range High1Powertrain
P0AEEDrive Motor Inverter Temperature Sensor A Circuit Range/Performance29Powertrain
P0AEE00Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine A' hat Funktionsstörung.2Powertrain
P0AEE16Temperature sensor A of power inverter 'Electric machine' has a malfunction. The limit value for electrical voltage has not been attained.1Powertrain
P0AEE62Plausibility of PCB temperature 2 versus other temperatures after long shut-down.1Powertrain
P0AEE84Out-of-range low on PCB temperature sensor 21Powertrain
P0AEE85Out-of-range high on PCB temperature sensor 21Powertrain
P0AEE96Temperature sensor A of power inverter 'Electric machine' has a malfunction. There is an internal component fault.1Powertrain
P0AEFMotor controller temperature sensor short circuit (SL)29Powertrain
P0AEF00Diagnosis to detect signal range check low at signal tSnsrPwrModlPha1Hs.1Powertrain
P0AF0Motor controller temperature sensor open circuit (SH)30Powertrain
P0AF000Diagnosis to detect signal range check high at signal tSnsrPwrModlPha1Hs.1Powertrain
P0AF1Drive Motor Inverter Temperature Sensor A Circuit Intermittent/Erratic23Powertrain
P0AF211Inverter Temperature Sensor AH Short to Ground1Powertrain
P0AF212Inverter Temperature Sensor AH Short to Battery1Powertrain
P0AF213Drive Motor Inverter Temperature Sensor 'B' Circuit. Circuit Open1Powertrain
P0AF264Inverter Temperature Sensor AH Plausibility Check Fault1Powertrain
P0AF285Inverter Temperature Sensor AH Out of Range High1Powertrain
P0AF300Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine B' hat Funktionsstörung.2Powertrain
P0AF362Der Temperatursensor 1 des Wechselrichters 'Elektrische Maschine B' hat Funktionsstörung. Der Signalvergleich ist fehlerhaft.1Powertrain
P0AF396Temperature sensor B of power inverter 'Electric machine' has a malfunction. There is an internal component fault.1Powertrain
P0AF400Diagnosis to detect signal range check low at signal tSnsrPwrModlPha1Ls.1Powertrain
P0AF500Diagnosis to detect signal range check high at signal tSnsrPwrModlPha1Ls.1Powertrain
P0AF800Undervoltage at KL402Powertrain
P0AF816HVDC Bus Undervoltage in Sensorless1Powertrain
P0AF817Bus Over Voltage Hardware Fault (FOV)1Powertrain
P0AF81CThe power supply of the high-voltage on-board electrical system has a malfunction.1Powertrain
P0AF8A2HVDC Bus Undervoltage1Powertrain
P0AF8A3HVDC Bus Over Voltage Fault (SW)1Powertrain
P0AF9Hybrid Battery System Voltage Unstable23Powertrain
P0AFAThe bus voltage is lower than the lower limit of the operating voltage.28Powertrain
P0AFA00The power supply of the high-voltage on-board electrical system is too low.1Powertrain

Some brand data is extracted from diagnostic files and may contain manufacturer-specific wording. General SAE J2012 descriptions are used where available.